NCC Class 10
Non-habitable buildings or structures.
Class 10a: sheds, carports and private garages.
Class 10c: a private bushfire shelter, associated with but not attached to a Class 1a building.
Garage, Carport & Fire Shelter
Dincel permanent formwork for structural concrete walls in garage, carport & fire shelter buildings. See the walls it suits, where they go and how they perform for fire, acoustics and structure.
Where Dincel is used
The walls Dincel is used for in a typical garage, carport & fire shelter building.
Ideal for
- Curved Walls
- Fire Rated Exterior Walls
- Retaining Walls
- Fire Rated Partition Walls
Internal ApplicationsGarage, Carport & Fire Shelter | NCC Class 10 |
|||||
|---|---|---|---|---|---|
| SYSTEM PERFORMANCE | |||||
| System Components | Dincel Profile | Min. Plaster board Thick-ness | Total Wall Width | Rw (Rw+Ctr) | Maximum FRL achievable |
|
DIN-IW1 Dincel Wall
left bare
left bare
|
110 | N/A | 110 | 48 (43) | 90/90/90¹ |
| 155 | N/A | 155 | 51 (45) | 180/180/180¹ | |
| 200 | N/A | 200 | 53 (48) | 240/240/240¹ | |
| 275 | N/A | 275 | 53 (48) | 240/240/240¹ | |
|
DIN-IW2 Dincel Wall
plasterboard
left bare
|
110 | 10 | 120 | 45 (41) | 90/90/90¹ |
| 155 | 13 | 168 | 50 (45) | 180/180/180¹ | |
| 200 | 10 | 210 | 51 (46) | 240/240/240¹ | |
| 275 | 10 | 285 | 51 (46) | 240/240/240¹ | |
|
DIN-IW3 Dincel Wall
plasterboard
plasterboard
|
110 | 10 | 130 | 45 (41) | 90/90/90¹ |
| 155 | 13 | 181 | 50 (45) | 180/180/180¹ | |
| 200 | 10 | 220 | 51 (46) | 240/240/240¹ | |
| 275 | 10 | 295 | 51 (46) | 240/240/240¹ | |
|
DIN-IW4 Dincel Wall
plasterboard
28mm furring channels (600 c/c, 30mm cavity), plasterboard
|
110 | 13 | 166 | 45 (42) | 90/90/90¹ |
| 155 | 10 | 205 | 48 (43) | 180/180/180¹ | |
| 200 | 10 | 250 | 53 (46) | 240/240/240¹ | |
| 275 | 10 | 325 | 53 (46) | 240/240/240¹ | |
|
DIN-IW5 Dincel Wall
plasterboard
28mm furring channels (600 c/c, 30mm cavity), 25mm glasswool (HD), plasterboard
|
110 | 10 | 160 | 53 (46) | 90/90/90¹ |
| 155 | 10 | 205 | 55 (48) | 180/180/180¹ | |
| 200 | 10 | 250 | 57 (50) | 240/240/240¹ | |
| 275 | 10 | 325 | 57 (50) | 240/240/240¹ | |
|
DIN-IW6 Dincel Wall
28mm furring channels (600 c/c, 45mm cavity), 25mm glasswool (HD), plasterboard
28mm furring channels (600 c/c, 45mm cavity), 25mm glasswool (HD), plasterboard
|
110 | 16 | 232 | 63 (50) | 90/90/90¹ |
| 155 | 13 | 271 | 60 (52) | 180/180/180¹ | |
| 200 | 13 | 316 | 63 (54) | 240/240/240¹ | |
| 275 | 13 | 391 | 63 (54) | 240/240/240¹ | |
|
DIN-IW7 Dincel Wall
left bare
51mm steel studs (600 c/c, 71mm cavity), plasterboard
|
110 | 10 | 191 | 51 (43) | 90/90/90¹ |
| 155 | 10 | 236 | 54 (45) | 180/180/180¹ | |
| 200 | 10 | 281 | 57 (47) | 240/240/240¹ | |
| 275 | 10 | 356 | 57 (47) | 240/240/240¹ | |
|
DIN-IW8 Dincel Wall
plasterboard
51mm steel studs (600 c/c, 71mm cavity), 50mm glasswool (LD), plasterboard
|
110 | 13 | 207 | 57 (50) | 90/90/90¹ |
| 155 | 13 | 252 | 63 (51) | 180/180/180¹ | |
| 200 | 10 | 291 | 61 (53) | 240/240/240¹ | |
| 275 | 10 | 366 | 61 (53) | 240/240/240¹ | |
|
DIN-IW9 Dincel Wall
28mm furring channel (600 c/c, 30mm cavity), plasterboard
51mm steel studs (600 c/c, 71mm cavity), plasterboard
|
110 | 10 | 231 | 47 (41) | 90/90/90¹ |
| 155 | 10 | 276 | 51 (43) | 180/180/180¹ | |
| 200 | 10 | 321 | 55 (46) | 240/240/240¹ | |
| 275 | 10 | 396 | 55 (46) | 240/240/240¹ | |
|
DIN-IW10 Dincel Wall
28mm furring channel (600 c/c, 30mm cavity), plasterboard
51mm steel studs (600 c/c, 71mm cavity), 50mm glasswool (LD), plasterboard
|
110 | 13 | 237 | 57 (50) | 90/90/90¹ |
| 155 | 13 | 282 | 63 (51) | 180/180/180¹ | |
| 200 | 13 | 327 | 61 (53) | 240/240/240¹ | |
| 275 | 13 | 402 | 61 (53) | 240/240/240¹ | |
|
DIN-IW11 Dincel Wall
28mm furring channel (600 c/c, 30mm cavity), 25mm glasswool (HD), plasterboard
51mm steel studs (600 c/c, 71mm cavity), 50mm glasswool (LD), plasterboard
|
110 | HD13 | 237 | 62 (50) | 90/90/90¹ |
| 155 | HD13 | 282 | 67 (52) | 180/180/180¹ | |
| 200 | HD13 | 327 | 68 (53) | 240/240/240¹ | |
| 275 | HD13 | 402 | 68 (53) | 240/240/240¹ | |
External ApplicationsGarage, Carport & Fire Shelter | NCC Class 10 |
|||
|---|---|---|---|
| SYSTEM PERFORMANCE | |||
| System Components | Dincel Profile | Total Wall Width | Maximum FRL achievable |
|
DIN-EW1 Dincel Wall
left bare
left bare
|
110 | 110 | 90/90/90¹ |
| 155 | 155 | 180/180/180¹ | |
| 200 | 200 | 240/240/240¹ | |
| 275 | 275 | 240/240/240¹ | |
|
DIN-EW2 Dincel Wall
choice of finish: paint, render or cladding
left bare
|
110 | 110 | 90/90/90¹ |
| 155 | 155 | 180/180/180¹ | |
| 200 | 200 | 240/240/240¹ | |
| 275 | 275 | 240/240/240¹ | |
|
DIN-EW3 Dincel Wall
left bare
50mm+ cavity, secondary wall for habitable room (either 110 Dincel, lightweight partition, masonry or dry wall)
|
110 | 283 | 90/90/90¹ |
| 155 | 328 | 180/180/180¹ | |
| 200 | 373 | 240/240/240¹ | |
| 275 | 448 | 240/240/240¹ | |
|
DIN-EW4 Dincel Wall
choice of finish: paint, render or cladding
40mm insulation board, 28mm furring channel on clips, 13mm plasterboard
|
110 | 191 | 90/90/90¹ |
| 155 | 236 | 180/180/180¹ | |
| 200 | 281 | 240/240/240¹ | |
| 275 | 356 | 240/240/240¹ | |
|
DIN-EW5 Dincel Wall
110mm brick veneer w/20mm cavity
40mm insulation board, 28mm furring channel on clips, 13mm plasterboard
|
110 | 321 | 90/90/90¹ |
| 155 | 366 | 180/180/180¹ | |
| 200 | 411 | 240/240/240¹ | |
| 275 | 486 | 240/240/240¹ | |
|
DIN-EW6 Dincel Wall
Insulated panel system on top hats
28mm furring channels on clips, 13mm plasterboard
|
110 | 268 | 90/90/90¹ |
| 155 | 313 | 180/180/180¹ | |
| 200 | 358 | 240/240/240¹ | |
| 275 | 433 | 240/240/240¹ | |
The ‘NCC/Other requirements’ information provided above is for guidance purposes only, please check with your consultants for specific requirements for your project.
The above requirements are based upon the NCC deemed-to-satisfy provisions (Specification C1.1 and F5.0 - F5.5)
The above performance is based on the following product densities:
- 10mm thick plasterboard - 650 kg/m³ bulk density
- 13mm thick plasterboard - 623 kg/m³ bulk density
- HD13mm thick plasterboard (HD = High Density, typically fire rated plasterboard) - 808 kg/m³ bulk density
- 16mm thick plasterboard - 766 kg/m³ bulk density
- 25mm thick glasswool insulation (HD) - 24 kg/m³ bulk density
- 50mm thick glasswool insulation (LD) - 11 kg/m³ bulk density
- Concrete within Dincel formwork - 2350 kg/m³ bulk density
¹Dependant on design and wall loading. 'Structural Adequacy' component of FRL must be calculated and provided by the project's structural engineer, in accordance to AS3600, Eurocode or other relevant concrete design codes.
²FRL requirement is based upon a wall with a distance of less than 1.5m from a fire source feature. Please check the NCC for other FRL requirements which may be applicable to your project.
³Dincel recommends the 275 profile for permanently submerged applications due to enhanced design. For more information please refer to waterproofing documentation on our website.
Garage, Carport & Fire Shelter case studies
Projects built with Dincel Structural Walling.